A/TT1K-BP-4-GD-10'CL2P - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Bullet Probe, 1", 10' Plenum Cable, Galvanized Enclosure, 4-20mA Output
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
142043
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/TT1K-BP-4-GD-10'CL2P - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI Transmitter Bullet Probe Series features a two-wire, 4 to 20 mA loop powered output signal with an optional 3-Wire voltage output signal available. All transmitters include Zero and Span adjustments for field calibration and are calibrated using NIST Certified Calibration equipment. We recommend the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to help eliminate the possibility of noise being introduced onto the signal lines. The sensor assemblies are manufactured using a 2-conductor unshielded FEP/FEP Plenum rated, unshielded cable and ACI’s proven double encapsulation process to eliminate the effects of moisture on the sensors as well as increased response times using our high quality, thermally conductive epoxy. The Bullet Probe remote sensors include an optional 10 or 20 Foot Plenum rated cable for use in remote sensor applications. All TT100 and TT1K Series Bullet Probe transmitter’s sensor leads may be shortened in the field as needed but all Matched TTM100 and TTM1K Series transmitter’s sensor leads should not be shortened due to the impact that it would have on the calibration accuracy of the sensor and transmitter. Optional NEMA/IP rated weather proof enclosures are available as specified on the back of the product data sheet. For best accuracy, ACI recommends the use of the A/TTM Series Matched transmitters with 3 or 5 Point NIST Calibration Certificate, since they include a second calibration step in which the RTD and transmitter are calibrated together as a system.
Applications: Chilled Water Systems, Hot Water Systems, Boilers, Pumps, Compressors, Chillers, Remote Sensing, Process Control
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/100-3W-I-2.5'-BB-NIST - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Immersion, 2.5', NEMA 3R Enclosure, NIST Cert
H1066 - ACI
Automation Field Components
NITROGEN, 34 LITERS
H107220.9VN - ACI
Automation Field Components
20.90% OXYGEN, 34 LITERS
RCT36-5000 - ACI
Automation Field Components
36" Rogowski Coil, 25 to 6000A, 10.67" Window, Output@1000A = 20mV@50Hz / 24mV@60Hz, 6.5 ft Leads
A/1K-NI-RSO-A09-C5 - ACI
Automation Field Components
1,000 Ohm Nickel RTD, Room (R), Setpoint 0 to 2K Ohms, Override, Cool/Warm Sticker
A/RH2-TTM1K-D-BB-1 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, NEMA 3R Enclosure, ± 2% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 1-5VDC (Temp Output)
A/AN-BC-A-12'-BB - ACI
Automation Field Components
10,000 Ohm Thermistor w/11K Shunt, Copper Averaging, 12', NEMA 3R Enclosure
EPC2GFSB - ACI
Automation Field Components
Analog Input (0-5VDC), Pressure Output (0-10PSI), Dual Valve, Exhausts on Power Failure , Gauge, Steel Enclosure, (0-10V, 0-15V 0-20mA), (0-15PSI, 0-20PSI)