CDD5A101S - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Exposed push button momentary switch - N.O.
CDD5A101RS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Relay Output, Exposed push button momentary switch - N.O.
CDD5A101R - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Relay Output
CDD5A101PS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Linear slide pot for set point control, Exposed push button momentary switch - N.O.
CDD5A101PRS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Linear slide pot for set point control, Relay Output, Exposed push button momentary switch - N.O.
CDD5A101PR - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Linear slide pot for set point control, Relay Output
CDD5A101P - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD, Linear slide pot for set point control
CDD5A101 - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Viewable LCD
CDD5A100S - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Exposed push button momentary switch - N.O.
CDD5A100RS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Relay Output, Exposed push button momentary switch - N.O.
CDD5A100R - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Relay Output
CDD5A100PS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Linear slide pot for set point control, Exposed push button momentary switch - N.O.
CDD5A100PRS - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Linear slide pot for set point control, Relay Output, Exposed push button momentary switch - N.O.
CDD5A100PR - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Linear slide pot for set point control, Relay Output
CDD5A100P - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD, Linear slide pot for set point control
CDD5A100 - Greystone
Mahal Tip Karbondioksit Dedektörü
Room Carbon Dioxide Detector, 0-2000 ppm, Temperature & Humidity, 4-20 mA, Concealed LCD