A/RH1-100-2W-O - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 1% Accuracy, 100 Ohm RTD (Two Wires), Euro Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
136041
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/RH1-100-2W-O - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The A/RH Series (resistive temperature output) relative humidity transmitters utilize a capacitive sensing element to deliver a proportional analog output. The series features on board DIP switches which allow the user to select the desired output signal and can be powered by AC or DC power sources. Field calibration can be performed by using the on board increment and decrement DIP switches. These enhancements provide increased flexibility and outstanding long-term performance. The A/RH Series is covered by ACI's Five (5) Year Limited Warranty.
Part numbers in this series include: A/RH1-AN-O, A/RH1-CP-O, A/RH1-CSI-O, A/RH1-100-O, A/RH1-1K-O, A/RH1-1K-NI-O, A/RH1-10KE-O, A/RH1-10KE1-O, A/RH1-3K-O, A/RH1-20K-O, A/RH1-10KS-O, A/RH1-100KS-O, A/RH1-1.8K-O, A/RH1-AN-BC-O
- Single point field calibration
- Field selectable output signals (0-5 VDC, 0-10 VDC, 4-20 mA)
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TT100-INW-4'-4-EXPL - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Hazardous, Immersion, No Well, 4', 4-20mA Output
A/10KS-D-8'-PB - ACI
Automation Field Components
10,000 Ohm Thermistor, Duct, 8', Plastic Enclosure
A/100-3W-D-12'-PB - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Duct, 12', Plastic Enclosure
F200 - ACI
Automation Field Components
Monitoring Appliance (Temp/RH/Leak), (8) DI, (4) RJ-11 Inputs, Relay Output, Alarm, Logging, Trending, Protocols: TCP/IP, HTML, SMTP, Modbus TCP/IP, SNMP
A/DLP-015-W-U-N-B-0-C-0P-S - ACI
Automation Field Components
Differential Low Pressure, 15 inWC, Unidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 0-10VDC Output, No Nist, Standard
A/TUC2-AN-BC-0004 - ACI
Automation Field Components
10,000 Ohm Thermistor w/11K Shunt, Setpoint, LCD
A/RH3-TTM1K-O-4X-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, NEMA 4X Enclosure, ± 3% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)
A/RH3-TT1K-O-4X-1 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 3% Accuracy, Transmitter w/ 1,000 Ohm RTD, NEMA 4X Enclosure, 1-5VDC (Temp)