Q5-HCN-50P-0-X - ACI
Automation Field Components
Smart Sensor, Hydrogen Cyanide, 0-50 ppm, 3 SPDT Relays, NEMA 4X, 4-20mA, 2-10V, or Modbus RTU
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
146340
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
Q5-HCN-50P-0-X - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The B5/Q5 Toxic/Combustible Gas Detectors use various sensing technologies to detect a wide assortment of gases. These units are housed in a NEMA 4X rated plastic enclosure that will meet the most stringent applications. All models feature an internal clock, LCD Display for displaying gas concentrations and setup, LED Status Indication, integral buzzer with three user congurable relays and a number of dierent communication protocols for use with one of our gas controllers or your building management system. Factory calibrated sensor module replacements are available and are easily replaced in the eld by removing two screws on the previous module. All units should be checked for proper functionality and calibration once the replacement sensor module is reinstalled and has had a chance to warm up. A user selectable password can be used to protect the system integrity. The Q5 can be used as a standalone gas detector or in conjunction with the Q4C, M-Controller or Q-Controllers using the proprietary RS-485 Optomux communication protocol. The B5 uses BACnet™ MSTP (RS485) protocol to communicate directly with a BAS. Calibration gases and a 0.2 to 1 liter/minute ow limiting gas regulator are not available through ACI. These should be purchased through your local gas supply company or on-line companies such as Portagas® (Praxair®, Inc.) or Mesa Specialty Gases®. ACI also oers a full line of horns and strobes that can be used with the Gas detectors or building management system to alert building occupants of an alarm condition. Refer to all applicable Federal, State, Provincial and Local Health and Safety laws and regulations before using these products. The Q5/B5-GENL can be ordered to monitor specic combustible gases such as Gasoline, Ethanol, Diesel or Jet fuel. contact KONTROLYUM for specic gases
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TTM100-I-4'-2-GD - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD (NIST Cert), Immersion, Welded Well, 4', Galvanized Enclosure, 2-10VDC Output
A/RH2-CP-R2SO-A04-G5 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10,000 Ohm Thermistor (Type II), w/ Setpoint 1051.1 to 51.1 ohms, and Override, Blue/Red Sticker
B8-GENL-100L-0-X-PENTANE - ACI
Automation Field Components
Expl Proof Sensor, BACnet Protocol, Pentane, 0-100% LEL
A/RH2-1.8K-D-NIST - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, 1,800 Ohm Thermistor, Euro Enclosure, NIST Cert (Temp)
A/DLP-003-W-U-N-B-0-B-0P-S - ACI
Automation Field Components
Differential Low Pressure, 3 inWC, Unidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 0-5VDC Output, No Nist, Standard
A/10KS-R2SO-A26-C5 - ACI
Automation Field Components
10,000 Ohm Thermistor, Room (R2), Setpoint 886 to 1266, Override, Cool/Warm Sticker
FS-4 - ACI
Automation Field Components
Freeze Stat, 10' Capillary, Manual Reset, (2) SPDT
PTA - ACI
Automation Field Components
Pulse Width Modulation Input (0.1 to 10 sec), Analog Output, (0.02 to 5, 0.59 to 2.93, 0.1 to 25.5s Selectable)