AFP VERSION #6 - ACI
Automation Field Components
Analog Input (0-5VDC), Floating Point Output (75 sec), Version #6, (18, 360s Selectable),
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
130469
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
AFP VERSION #6 - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The AFP allows an analog signal to control a floating point actuator. It converts an analog signal into two relay contact outputs (one increase/one decrease). The isolated floating point output can be controlled by any one of eight analog input signal ranges (using offset jumper). On a loss of power, the AFP's output relays will be open, and no signal will be generated. The actuator will remain at the last commanded position unless it is "spring return". The AFP output rate of change (nine ranges, in four versions) is DIP switch selectable. In Version 4, the AFP relays stay on at minimum and maximum voltage. In Version 5, The AFP relays stay on with 5% of maximum or minimum input voltage. No overshoot on maximun or minimum input voltage. The AFP is covered by ACI's Two (2) Year Limited Warranty.
- Isolated Output
- Custom ranges
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TT100-D-4'-2-EXPL - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Hazardous, Duct, 4', 2-10VDC Output
A/1K-3W-HT-I-4'-BB - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, High Temperature Immersion, 4' 316SS, NEMA 3R Enclosure
A/CP-R2SO-232-A02-G5 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Room (R2), w/ Setpoint 0 to 20K, Override, RS232, Blue/Red Sticker
TUC2-CP-F1-1H-ZP-X-X-X-X - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Setpoint, LCD
A/RH1-TTM1K-RP2-6'-4X-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, 6' Plenum Cable, NEMA 4X Enclosure, ± 1% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)
A/WPR2-300-10-LCD - ACI
Automation Field Components
Wet Differential Pressure, 0-30, 0-75, 0-150, 0-300 PSID (Default), 10' Cables, LCD, Outputs: 0-10 VDC (Default), 0-5 VDC, 4-20mA (Selectable)
A/RH2-TTM1K-D-BB-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, NEMA 3R Enclosure, ± 2% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)
A/TT1K-SP-4 - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Wall Plate, Stainless Steel, 4-20mA Output