HATXDCA18JE003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
HATX Series Temperature Transmitter, High Accuracy Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, class A, 3600 mm (12'), 0-10 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
HATXDCA18JE003
Greystone
CANADA
- Features
- Comments (0)
HATXRPA22BD001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Remote Probe - strap-on, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/10 DIN, 100 mm (4"), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATXOSA48XA006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Outside Air, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, , 4-20 mA 2 or 3 wire, -50°C to 50°C (-58°F to 122°F)
HATXDRA48HA003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Duct Average, rigid stainless steel probe, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 900 mm (36"), 4-20 mA 2 or 3 wire, 0°C to 100°C (32°F to 212°F)
HATXDRA18GA001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Duct Average, rigid stainless steel probe, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, class A, 600 mm (24"), 4-20 mA 2 or 3 wire, 0°C to 35°C (32°F to 95°F)
HATXDFA22LE002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Duct Average, flexible cable, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/10 DIN, 7300 mm (24'), 0-10 VDC 3 wire, 0°C to 50°C (32°F to 122°F)
HATXDFA22ID001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Duct Average, flexible cable, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/10 DIN, 1800 mm (6'), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATXDCE48KD001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, with thread adaptor and cable gland adaptor, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20'), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATXAPA22CE006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter, High Accuracy All Purpose Duct/Immersion, ABS enclosure with hinged and gasketed cover, 1000 ohm platinum, 3 wire, IEC 751, 385 alpha, thin film, 1/10 DIN, 150 mm (6"), 0-10 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)