GDTCNRSMVBR1XXX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Viewable LCD, BACnet, One (1) Adjustable Relay, No alarm, No temperature sensor
GDTCNRSMVBR1XTX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Viewable LCD, BACnet, One (1) Adjustable Relay, No alarm, Analog Transmitter
GDTCNRSMVBR1AXX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Viewable LCD, BACnet, One (1) Adjustable Relay, Audible(Buzzer)/Visual(Strobe), No temperature sensor
GDTCNRSMVBR1ATX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Viewable LCD, BACnet, One (1) Adjustable Relay, Audible(Buzzer)/Visual(Strobe), Analog Transmitter
GDTCNRSMCVXXXXX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, No temperature sensor
GDTCNRSMCVXXXTX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, Analog Transmitter
GDTCNRSMCVXXX59 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 10,000 Ohm, NTC Thermistor, ±0.2 C
GDTCNRSMCVXXX24 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 10,000 Ohm, type 2, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX20 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 20,000 Ohm, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX14 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 10,000 Ohm, type 3, NTC thermistor, ±0.2 C c/w 11K shunt resistor
GDTCNRSMCVXXX13 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 1000 Ohm nickel, class B, DIN 43760
GDTCNRSMCVXXX12 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 1000 Ohm platinum, IEC 751, 385 alpha, thin film
GDTCNRSMCVXXX08 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 2.252K Ohm, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX07 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 10,000 Ohm, type 3, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX06 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 3000 Ohm, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX05 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 1801 Ohm, NTC thermistor, ±0.2 C
GDTCNRSMCVXXX02 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, No alarm, 100 Ohm platinum, IEC 751, 385 alpha, thin film, 3 wire
GDTCNRSMCVXXAXX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, Audible(Buzzer)/Visual(Strobe), No temperature sensor
GDTCNRSMCVXXATX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, Audible(Buzzer)/Visual(Strobe), Analog Transmitter
GDTCNRSMCVXXA59 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide/Nitrogen Dioxide-Remote, Surface mount, Concealed LCD, Voltage (0-5Vdc/0-10Vdc), No Relay, Audible(Buzzer)/Visual(Strobe), 10,000 Ohm, NTC Thermistor, ±0.2 C