GDTCOXSMCIXXX13 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 1000 Ohm nickel, class B, DIN 43760
GDTCOXSMCIXXX12 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 1000 Ohm platinum, IEC 751, 385 alpha, thin film
GDTCOXSMCIXXX08 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 2.252K Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXX07 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 10,000 Ohm, type 3, NTC thermistor, ±0.2 C
GDTCOXSMCIXXX06 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 3000 Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXX05 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 1801 Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXX02 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, No alarm, 100 Ohm platinum, IEC 751, 385 alpha, thin film, 3 wire
GDTCOXSMCIXXAXX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), No temperature sensor
GDTCOXSMCIXXATX - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), Analog Transmitter
GDTCOXSMCIXXA59 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 10,000 Ohm, NTC Thermistor, ±0.2 C
GDTCOXSMCIXXA24 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 10,000 Ohm, type 2, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA20 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 20,000 Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA14 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 10,000 Ohm, type 3, NTC thermistor, ±0.2 C c/w 11K shunt resistor
GDTCOXSMCIXXA13 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 1000 Ohm nickel, class B, DIN 43760
GDTCOXSMCIXXA12 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 1000 Ohm platinum, IEC 751, 385 alpha, thin film
GDTCOXSMCIXXA08 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 2.252K Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA07 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 10,000 Ohm, type 3, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA06 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 3000 Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA05 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 1801 Ohm, NTC thermistor, ±0.2 C
GDTCOXSMCIXXA02 - Greystone
Carbon Monoxide / Nitrogen Dioxide Combination Gas Detector
Gas Detector, Carbon Monoxide, Surface mount, Concealed LCD, Current (4-20mA), No Relay, Audible(Buzzer)/Visual(Strobe), 100 Ohm platinum, IEC 751, 385 alpha, thin film, 3 wire