TXDCA12KA003 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 6100 mm (20'), 4-20 mA 2 or 3 wire, 0°C to 100°C (32°F to 212°F)
TXDCA12KA002 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 6100 mm (20'), 4-20 mA 2 or 3 wire, 0°C to 50°C (32°F to 122°F)
TXDCA12KA001 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 6100 mm (20'), 4-20 mA 2 or 3 wire, 0°C to 35°C (32°F to 95°F)
TXDCA12JE006 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-10 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
TXDCA12JE003 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-10 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
TXDCA12JE002 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-10 VDC 3 wire, 0°C to 50°C (32°F to 122°F)
TXDCA12JE001 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-10 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
TXDCA12JD006 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-5 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
TXDCA12JD003 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-5 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
TXDCA12JD002 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-5 VDC 3 wire, 0°C to 50°C (32°F to 122°F)
TXDCA12JD001 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
TXDCA12JA006 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 4-20 mA 2 or 3 wire, -50°C to 50°C (-58°F to 122°F)
TXDCA12JA003 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 4-20 mA 2 or 3 wire, 0°C to 100°C (32°F to 212°F)
TXDCA12JA002 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 4-20 mA 2 or 3 wire, 0°C to 50°C (32°F to 122°F)
TXDCA12JA001 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 3600 mm (12'), 4-20 mA 2 or 3 wire, 0°C to 35°C (32°F to 95°F)
TXDCA12IE006 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 1800 mm (6'), 0-10 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
TXDCA12IE003 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 1800 mm (6'), 0-10 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
TXDCA12IE002 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 1800 mm (6'), 0-10 VDC 3 wire, 0°C to 50°C (32°F to 122°F)
TXDCA12IE001 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 1800 mm (6'), 0-10 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
TXDCA12ID006 - Greystone
Duct / Immersion Temperature Transmitter
Temperature Transmitter, Duct Average, copper probe, ABS enclosure with hinged and gasketed cover, 1000 Ohm platinum, IEC 751, 385 alpha, thin film, 1800 mm (6'), 0-5 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)