HATDDCFC48LE001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 0-10 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATDDCFC48LD006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 0-5 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
HATDDCFC48LD003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 0-5 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
HATDDCFC48LD002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 0-5 VDC 3 wire, 0°C to 50°C (32°F to122°F)
HATDDCFC48LD001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATDDCFC48LA006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 4-20 mA 2 or 3 wire, -50°C to 50°C (-58°F to 122°F)
HATDDCFC48LA003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 4-20 mA 2 or 3 wire, 0°C to 100°C (32°F to 212°F)
HATDDCFC48LA002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 4-20 mA 2 or 3 wire, 0°C to 50°C (32°F to122°F)
HATDDCFC48LA001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 7300 mm (24’), 4-20 mA 2 or 3 wire, 0°C to 35°C (32°F to 95°F)
HATDDCFC48KE006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-10 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
HATDDCFC48KE003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-10 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
HATDDCFC48KE002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-10 VDC 3 wire, 0°C to 50°C (32°F to122°F)
HATDDCFC48KE001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-10 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATDDCFC48KD006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-5 VDC 3 wire, -50°C to 50°C (-58°F to 122°F)
HATDDCFC48KD003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-5 VDC 3 wire, 0°C to 100°C (32°F to 212°F)
HATDDCFC48KD002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-5 VDC 3 wire, 0°C to 50°C (32°F to122°F)
HATDDCFC48KD001 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 0-5 VDC 3 wire, 0°C to 35°C (32°F to 95°F)
HATDDCFC48KA006 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 4-20 mA 2 or 3 wire, -50°C to 50°C (-58°F to 122°F)
HATDDCFC48KA003 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 4-20 mA 2 or 3 wire, 0°C to 100°C (32°F to 212°F)
HATDDCFC48KA002 - Greystone
High Accuracy Duct / Immersion Temperature Transmitter
Temperature Transmitter with Display Series, High Accuracy Duct Average, copper probe, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, Celsius, 1000 ohm platinum, 2 wire, IEC 751, 385 alpha, thin film, 1/3 DIN, 6100 mm (20’), 4-20 mA 2 or 3 wire, 0°C to 50°C (32°F to122°F)