CDD4B400T6R - Greystone
Outside Air Carbon Dioxide Sensor
CDD4B Series Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 3000 Ohm, NTC Thermistor, ±0.2 C, Relay Output
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
CDD4B400T6R
Greystone
CANADA
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
CDD4B400T6R - Greystone
Outside Air Carbon Dioxide Sensor
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
CDD4B Series Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 3000 Ohm, NTC Thermistor, ±0.2 C, Relay Output
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :GREYSTONE branded products are imported from Canada factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
CDD4B400T8 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 2.252K Ohm, NTC Thermistor, ±0.2 C
CDD4B400T7R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C, Relay Output
CDD4B400T2 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 100 Ohm Plat. IEC 751, 385 Alpha, thin film
CDD4B300T7 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C
CDD4B300T2 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 100 Ohm Plat. IEC 751, 385 Alpha, thin film
CDD4B300T14R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C c/w 11K shunt resistor, Relay Output
CDD4B300T14 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C c/w 11K shunt resistor
CDD4B300 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure