CDD4B400T59 - Greystone
Outside Air Carbon Dioxide Sensor
CDD4B Series Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 10,000 O NTC Thermistor, ±0.2 C
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
CDD4B400T59
Greystone
CANADA
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
CDD4B400T59 - Greystone
Outside Air Carbon Dioxide Sensor
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
CDD4B Series Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 10,000 O NTC Thermistor, ±0.2 C
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :GREYSTONE branded products are imported from Canada factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
CDD4B400T2R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with non-heated enclosure, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Relay Output
CDD4B300T6R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 3000 Ohm, NTC Thermistor, ±0.2 C, Relay Output
CDD4B300T59R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 10,000 O NTC Thermistor, ±0.2 C, Relay Output
CDD4B300T5 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 1801 Ohm, NTC Thermistor, ±0.2 C
CDD4B300T24 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 10,000 Ohm, type 2, NTC Thermistor, ±0.2 C
CDD4B300T13R - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 1000 Ohm Nickel, Class B, DIN 43760, Relay Output
CDD4B300T13 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 1000 Ohm Nickel, Class B, DIN 43760
CDD4B300T12 - Greystone
Outside Air Carbon Dioxide Sensor
Outside Air Carbon Dioxide Sensor, 0-20,000 ppm, with heated enclosure, 1000 Ohm Platinum, IEC 751, 385 Alpha, thin film