CD2RMCC05RXP02 - Greystone
Room Carbon Dioxide Sensor
CD2RMC Series Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 1801 Ohm, NTC Thermistor, ±0.2 C, Adjustable relay, No override, 2000 - 3000 ohms
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
CD2RMCC05RXP02
Greystone
CANADA
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
CD2RMCC05RXP02 - Greystone
Room Carbon Dioxide Sensor
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
CD2RMC Series Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 1801 Ohm, NTC Thermistor, ±0.2 C, Adjustable relay, No override, 2000 - 3000 ohms
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :GREYSTONE branded products are imported from Canada factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
CD2RMCV14RSXXX - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Viewable LCD, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C c/w 11K shunt resistor, Adjustable relay, Override switch, No setpoint
CD2RMCV13RXP00 - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Viewable LCD, 1000 Ohm Nickel, Class B, DIN 43760, Adjustable relay, No override, 0 - 10,000 ohms
CD2RMCV08XSXXX - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Viewable LCD, 2.252K Ohm, NTC Thermistor, ±0.2 C, No relay, Override switch, No setpoint
CD2RMCV07RXP00 - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Viewable LCD, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C, Adjustable relay, No override, 0 - 10,000 ohms
CD2RMCC12XXP02 - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 1000 Ohm Platinum, IEC 751, 385 Alpha, thin film, No relay, No override, 2000 - 3000 ohms
CD2RMCC12RXXXX - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 1000 Ohm Platinum, IEC 751, 385 Alpha, thin film, Adjustable relay, No override, No setpoint
CD2RMCC12RSP02 - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 1000 Ohm Platinum, IEC 751, 385 Alpha, thin film, Adjustable relay, Override switch, 2000 - 3000 ohms
CD2RMCC08RXP02 - Greystone
Room Carbon Dioxide Sensor
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 2.252K Ohm, NTC Thermistor, ±0.2 C, Adjustable relay, No override, 2000 - 3000 ohms