B5-CL2-5P-O-X - ACI
Automation Field Components
BACnet MSTP, Smart Sensor, Chlorine, 0-5 ppm, 3 SPDT Relays, NEMA 4X
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
135328
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
B5-CL2-5P-O-X - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The B5/Q5 Toxic/Combustible Gas Detectors use various sensing technologies to detect a wide assortment of gases. These units are housed in a NEMA 4X rated plastic enclosure that will meet the most stringent applications. All models feature an internal clock, LCD Display for displaying gas concentrations and setup, LED Status Indication, integral buzzer with three user configurable relays and a number of different communication protocols for use with one of our gas controllers or your building management system. Factory calibrated sensor module replacements are available and are easily replaced in the field by removing two screws on the previous module. All units should be checked for proper functionality and calibration once the replacement sensor module is reinstalled and has had a chance to warm up. A user selectable password can be used to protect the system integrity. The Q5 can be used as a standalone controller or in conjunction with the Q4C, M-Controller or Q-Controllers using the proprietary RS-485 Optomux communication protocol. The B5 uses BACnet MSTP (RS485) protocol to communicate directly with a BAS.
Replacement Sensors (pre-calibrated) are available at:Replacement Sensors
Veris HWLP1T1, HWLP1T3, HWLP2T1, HWLP2XX, HWLPHTX,
Alerton BACtalk, WEBtalk, Viewport, Envision, Compass software
Honeywell Excel Web II, XL2026B2A, TB7600, Spyder BACnet
Reliable Controls MACH-System, MACH-Global, MACH-Zone, MACH-Net
Greystone HANTRC, HANTO, HANTD, NTO, NTD, CMD, CDD3, ULP, RPC, NTRC, UP, DWDT, ULP2-BAC, ULP1-BAC, CDD3A101S
Veris HWLP1T1, HWLP1T3, HWLP2T1, HWLP2XX, HWLPHTX,
Alerton BACtalk, WEBtalk, Viewport, Envision, Compass software
Honeywell Excel Web II, XL2026B2A, TB7600, Spyder BACnet
Reliable Controls MACH-System, MACH-Global, MACH-Zone, MACH-Net
Greystone HANTRC, HANTO, HANTD, NTO, NTD, CMD, CDD3, ULP, RPC, NTRC, UP, DWDT, ULP2-BAC, ULP1-BAC, CDD3A101S
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/10KS-DO-6' - ACI
Automation Field Components
10,000 Ohm Thermistor, Duct, Without Box, 6'
A/3K-D-12'-4X - ACI
Automation Field Components
3,000 Ohm Thermistor, Duct, 12', NEMA 4X Enclosure
A/1K-2W-S10-4X - ACI
Automation Field Components
1,000 Ohm (Two Wires) RTD, Strap On, 10" Strap, NEMA 4X Enclosure
A/TUCH2-CP-0172 - ACI
Automation Field Components
LCD, RH2%, SET, O/R, DEG F
A/MLP2-300-P-U-A-C-0P - ACI
Automation Field Components
Differential Pressure, Panel Mount, 300 pascals, UniDirectional, +/- 0.5% FSO, 0-10VDC
A/100KS-AP - ACI
Automation Field Components
100,000 Ohm Thermistor, Wall Plate, Aluminum
ASENSE-D-REL - ACI
Automation Field Components
Carbon Dioxide Sensor, Duct Mount, 0-2000 PPM, Relay and Temperature, Relay, 0-10VDC & 4-20mA
A/RH3-CP-RO - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 10K Ohm Thermistor (Type II), w/ Override