ACUCT-H040-20:333 - ACI
Automation Field Components
Current Transformer, 20A, Hinged Split Core, 0.4" Aperture, 333mV Output, 2.5m Leads
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
148158
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
ACUCT-H040-20:333 - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The Hinged Split-Core Current Transformers are designed to convert an AC operating current into a low voltage AC millivolt signal for use with microprocessor-based circuits that require maximum accuracy and precision. These ultra-compact and light-weight hinged split-core current transformers are designed for installation on branch circuits within the electrical panel. The Hinged Split-Core CT Series is ideal for easy installation without disconnecting cables. Hinged Split-Core CTs come standard unterminated stripped and tinned lead wires for easy connection to any of the Single or 3 Phase ACI power meter. CT models listed here are compatible with the ACI KW350-P1-D-S-SC, KW320-P1-D-W-SC-XX, KW320-P1-D-W-SC-PC, KW1850-P1-D-W, and KW1850-P1-D-S Power Meters where typical power measurements are required. For best accuracy, CTs should be selected based upon the size of the conductors being monitored by selecting the proper window size and referencing the expected maximum and minimum currents for the targeted application. The acceptable Measurement Current Range is referenced in the ordering grid table. Please contact KONTROLYUM for more information regarding the Hinged Split-Core Current Transformers.
Applications: Retro Fitting Sub-Metering Electrical Panel, Equipment Load Monitoring, Industrial Applications, Predicted Maintenance, Renewable Energy, Overhead Cost Reduction, “NET ZERO” Buildings, LEED Buildings, Green Buildings, and Refrigeration
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/1K-3W-RA-18'-PB - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, Rigid Probe Averaging, 18', Plastic Enclosure
A/ULT-001-4X-06-TB853 - ACI
Automation Field Components
(2)Transmitters w/1,000 Ohm RTD, Low Temperature 2" Probe, 316SS, 6' Plenum Cable, 4X, 4-20mA, 8.5 oz Bottle w/ Glass Beads (Three Sensor Wells), NIST Cert
A/CO2-R2SO-AN-A10-G5 - ACI
Automation Field Components
Carbon Dioxide Sensor, Room, 0-2000 PPM, (0-5V, 0-10V, 4-20mA), Temp (10K Type III), Setpoint (0-1K), Blue/Red Sticker, Override
A/DLP-2D5-W-U-N-B-1-C-3P-S - ACI
Automation Field Components
Differential Low Pressure, 2.5 inWC, Unidirectional, No Display, 0.25% Accuracy, w/ Pitot Tube, 0-10VDC Output, 3 Point Nist, Standard
A/MLP2-010-W-B-A-B-0P - ACI
Automation Field Components
Differential Pressure, Panel Mount, 10.00 inWC, BiDirectional, +/- 0.5% FSO, 0-5VDC
A/3K-I-6”-4X - ACI
Automation Field Components
3,000 Ohm Thermistor, Immersion, Welded Well, 6", NEMA 4X Enclosure
ESENSE-D-LCD - ACI
Automation Field Components
Carbon Dioxide Sensor, Duct Mount, 0-2000 PPM, LCD, 0-10VDC & 4-20mA Output
A/1K-3W-A-50'-BB - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, Copper Averaging, 50', NEMA 3R Enclosure