A/TT1K-RA-24'-4-GD - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Rigid Probe Averaging, 24', Galvanized Enclosure, 4-20mA Output
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
118295
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/TT1K-RA-24'-4-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI Transmitter Rigid Averaging Series features a two-wire, 4 to 20 mA loop-powered output signal with an optional 3-Wire voltage output signal available. The Rigid Averaging sensors are designed to be installed in small to medium size ducts to give you a better average compared to that of a single point sensor. All transmitters include Zero and Span adjustments for field calibration and are calibrated using NIST Certified Calibration equipment. ACI recommends the use of an 18 to 22 AWG shielded cable for all temperature transmitter installations to help eliminate the possibility of noise being introduced onto the signal lines. The 1K Ohm Rigid Averaging sensor assemblies include a continuous sensing element that covers the entire length of the stainless steel probe and are manufactured using colored Etched Teflon lead wires to differentiate between the sensor types. All units are hermetically sealed using our epoxy material to eliminate the effects of moisture on the sensors. The Rigid Averaging transmitters include a foam pad to properly seal the duct and limit vibration once installed. Optional NEMA/IP rated weather proof enclosures are available as specified on the back of the product data sheet. For best accuracy, ACI recommends the use of the A/TTM Series Matched transmitters with a 3 or 5 Point NIST Calibration Certificate, since they include a second calibration process in which the RTD and transmitter are calibrated together as a system. On larger ducts, ACI’s bendable copper averaging transmitter should be used for better coverage and control of the air inside of the duct. Applications: Roof Top Units, Air Handlers, Monitoring Supply/Discharge/Return/Mixed Air Temperatures, Data Centers, Hospitals
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/100-3W-HT-INW-4'-GD - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, High Temperature Immersion, No Well, 4', Galvanized Enclosure
ACUCT-200-600:333 - ACI
Automation Field Components
Current Transformer, 600A, Split Core, 2.0" Aperture, 333mV Output, 2.5m Leads
TUCH2-ANF11EB0CX-205XXXXXX - ACI
Automation Field Components
LCD, RH2%, SET, O/R, DEG F
A/DLP-010-W-U-N-A-0-B-0P-S - ACI
Automation Field Components
Differential Low Pressure, 10 inWC, Unidirectional, No Display, 0.50% Accuracy, No Pitot Tube, 0-5VDC Output, No Nist, Standard
A/100KS-A-8'-BB - ACI
Automation Field Components
100,000 Ohm Thermistor, Copper Averaging, 8', NEMA 3R Enclosure
RN (0-40K) - ACI
Automation Field Components
Resistor Network (0 to 40K Ohms)
A/100-3W-BP-20'-CL2P - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Bullet Probe, 1", 20' Plenum Cable
DBL-205D - ACI
Automation Field Components
Differential Pressure Switch, 0.8 to 4.0 inWC, SPDT, Auto Reset, NEMA 3 Enclosure