A/TT1K-LT-D-8'-4-GD - ACI
Automation Field Components
Transmitter w/ 1000 Ohm RTD, Low Temperature Duct, 8' 316 SS, Galvanized Enclosure, 4-20mA Output
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
119078
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/TT1K-LT-D-8'-4-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI Low Temperature Duct Series sensors and transmitters are a single point duct sensor featuring a three wire RTD sensor assembly using Teflon Lead wires and a 316 Series stainless steel probe. The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the third wire (White) wire going to the second RTD Terminal block. The purpose of the third wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD. The operating specifications are for both the sensor and transmitter as designated in the specification table. Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure. NIST Certificates are available for all of the configurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, in order to remove most of the sensor error over the calibrated temperature span of the transmitter. Applications: Pharmaceutical, Liquid Nitrogen, Refrigerators, Freezers, Hydronic Heating, Remote Sensor Applications
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/100KS-INW-2.5'-BB - ACI
Automation Field Components
100,000 Ohm Thermistor, Immersion, No Well, 2.5', NEMA 3R Enclosure
A/1.8K-INW-6'-GD - ACI
Automation Field Components
1,800 Ohm Thermistor, Immersion, No Well, 6', Galvanized Enclosure
A/10KS-D-4'-PB - ACI
Automation Field Components
10,000 Ohm Thermistor, Duct, 4', Plastic Enclosure
A/RH3-50K-SP-05 - ACI
Automation Field Components
Relative Humidity, RH Output: 0-5 VDC (Default), Wall Plate 304SS, ± 3% Accuracy, 50,000 Ohm Thermistor, Stainless Steel
A/TT100-SP-1 - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Wall Plate, Stainless Steel, 1-5VDC Output
A/TUCH2-AN-0060 - ACI
Automation Field Components
LCD, RH3%, SET, DEG F
A/RH2-AN-R2LO - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 10K Ohm Thermistor (Type III), Custom Logo, w/ Override
A/RH5-TT1K-O-4X-2 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 5% Accuracy, Transmitter w/ 1,000 Ohm RTD, NEMA 4X Enclosure, 2-10VDC (Temp)