A/TT1K-HT-INW-2.5'-4-GD - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, High Temperature Immersion, No Well, 2.5', Galvanized Enclosure, 4-20mA Output
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
118396
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/TT1K-HT-INW-2.5'-4-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI High Temperature Immersion Series sensors and transmitters are a single point immersion sensor featuring a three wire RTD sensor assembly using Nickel Fiberglass Lead wires, a 316 Series stainless steel probe, and a Machined 304 SS Steel thermowell. The “INW” version of the product can be ordered without the thermowell for applications in which there is an existing thermowell, increased design parameters or other materials are required for higher corrosion resistance. The three wire sensors can be used with a two wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the 3rd wire (White) wire going to the second RTD Terminal block. The purpose of the 3rd wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD. The operating specications are for both the sensor and transmitter as designated in the specifi
cation table. Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure. NIST Certificates are available for all of the congurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters with a 3 or 5 Point NIST Calibration Certicate since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, which removes most of the sensor error over the calibrated temperature span of the transmitter.
Applications: Burners, Boilers, Stacks, Exhaust, Incinerators, Ovens, Plastics Processing, Process Heating, Process Control, Steam Lines
The ACI High Temperature Immersion Sensors and Transmitters Series are covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/20K-IM-6'-PB - ACI
Automation Field Components
20,000 Ohm Thermistor, Immersion, Machined Well, 6', Plastic Enclosure
A/AN-D-18'-GD - ACI
Automation Field Components
10,000 Ohm Thermistor (Type III), Duct, 18', Galvanized Enclosure
ACUCT-H040-50:333 - ACI
Automation Field Components
Current Transformer, 50A, Hinged Split Core, 0.4" Aperture, 333mV Output, 2.5m Leads
A/50K-A-12'-GD - ACI
Automation Field Components
50,000 Ohm Thermistor, Copper Averaging, 12', Galvanized Enclosure
A/MLP2-300-P-U-A-B-0P - ACI
Automation Field Components
Differential Pressure, Panel Mount, 300 pascals, UniDirectional, +/- 0.5% FSO, 0-5VDC
A/20K-FA-8'-GD - ACI
Automation Field Components
20,000 Ohm Thermistor, Flexible Cable Averaging, 8', Galvanized Enclosure
A/RH2-AN-R - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 10K Ohm Thermistor (Type III)
A/TT1K-O-4-4X - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Outside Air, NEMA 4X Enclosure, 4-20mA Output