A/RH1-50K-O - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 1% Accuracy, 50,000 Ohm Thermistor, Euro Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
147036
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/RH1-50K-O - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI Relative Humidity with Thermistor Outside Air Series utilizes a thermoset polymer capacitive sensing element with factory applied hygroscopic filter to deliver a proportional analog current or voltage output signal. The hygroscopic filter provides added resistance to moisture, dust, and other chemicals for greater long term reliability. The RH Outside Air transmitter features integral DIP switches for field selection of the proper output signal and supply voltage to meet your applications requirements. Each unit also contains 0%, 50%, and 100% test options to verify that the transmitter is both working and wired properly. Field calibration also can be performed by using the increment and decrement calibration DIP switches without the need to replace the sensing element. These enhancements provide increased flexibility and outstanding long-term reliability. Outside Air configurations feature a weatherproof Euro style enclosure with gasketed cover and conformally coated circuit boards for added moisture and chemical resistance. Three and Five-point NIST Calibration Certificates are available upon request but they must be ordered separately. Applications: Monitor Outdoor Air Humidity, Economizer Control, Psychrometric calculations such as Enthalpy and Dew point, Wash down Applications
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/CSI-D-6'-GD - ACI
Automation Field Components
10,000 Ohm (CSI) Thermistor, Duct, 6', Galvanized Enclosure
A/TT1K-LT-INW-2.5'-1-BB - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Low Temperature Immersion, No Well, 2.5', NEMA 3R Enclosure, 1-5VDC Output
A/CP-R2S-A08-G5 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Room (R2), Setpoint, 1K to 11K Ohms, Blue/Red Sticker
A/AN-R2SO-A16-C5 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type III), Room (R2), Setpoint 0 to 5K Ohms, Override, Cool/Warm Sticker
A/3K-RSO-A07-C5 - ACI
Automation Field Components
3,000 Ohm Thermistor, Room (R), Setpoint 10 to 30K Ohms, Override, Cool/Warm Sticker
A/10K-E1-FA-12'-GD - ACI
Automation Field Components
10,000 Ohm (E1) Thermistor, Flexible Cable Averaging, 12', Galvanized Enclosure
A/RH2-R-LCD-010 - ACI
Automation Field Components
Relative Humidity, Room, Humidity with LCD, ± 2% Accuracy, 0-10 VDC
A/RH2-R2 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy