The A/DIFF-ENT is an enthalpy controller which measures and converts temperature and humidity into a sources relay output. The supply voltage to the A/DIFF-ENT is common to both the N/O or N/C contacts of the 10A Form 1C Relay. Typically used in conjunction with the A/DIFF-ENT, the A/ENT converts a capacitive type humidity sensor into a linear 2-wire, 4 to 20 mA output. Its signal is proportional to a scale of 0 to 50 BTU's and is geared towards OEMs of economizers and other devices that require an enthalpy input, or economizer control. Each unit in this series features a conformally coated circuit board and jumper selectable elevation setting. The A/DIFF-ENT is covered by ACI's Five (5) Year Limited Warranty.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TT100-I-6'-2-GD - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Immersion, Welded Well, 6', Galvanized Enclosure, 2-10VDC Output
A/1K-NI-I-4'-GD - ACI
Automation Field Components
1,000 Ohm Nickel RTD, Immersion, Welded Well, 4', Galvanized Enclosure
A/RH2-TT1K-O-SUN-2 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, Transmitter w/ 1000 Ohm RTD, Sun Shield, 2-10VDC (Temp)
A/DLP-D10-W-U-D-A-3-B-0P-S - ACI
Automation Field Components
Differential Low Pressure, 0.10 inWC, Unidirectional, LCD, 0.50% Accuracy, w/ Pitot Tube and Din Rail, 0-5VDC Output, No Nist, Standard
A/FLS-10-A - ACI
Automation Field Components
Freeze Stat (FLS), 10' Capillary, Automatic Reset, 4 Wires, 2 Circuits (Two Simultaneously Switching Contacts)
CT-R36-A4-U-15M - ACI
Automation Field Components
Revenue Grade CT, Rocoil, 35.4" L, 131 mV /1000A @ 60 Hz, 15 m Leads
A/CP-SP-OR-232 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Wall Plate, Stainless Steel, w/ Override, RS232
A/3K-S-4X - ACI
Automation Field Components
3,000 Ohm Thermistor, Strap On, NEMA 4X Enclosure