A/CO2-R2S-AN-A02-G5 - ACI
Automation Field Components
Carbon Dioxide Sensor, Room, 0-2000 PPM (0-5V, 0-10V, 4-20mA), Temp 10K (Type III), Setpoint(0 to 20K), Blue/Red Sticker
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
147543
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/CO2-R2S-AN-A02-G5 - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI CO2 (A/CO2 R2) room transmitter monitors the carbon dioxide (CO2) levels in industrial, school, and office type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non dispersive infrared technology and is a cost efficient solution for measuring carbon dioxide (CO2) levels for building climate control. In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default output is 4-20 mA, whereas 0-5 VDC and 0-10 VDC outputs are able to be field selected via integral dip switches. Thermistor temperature outputs, along with setpoint and override, are available as options for room configurations. The A/CO2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate. The A/CO2 Series is covered by ACI's Five (5) Year Limited Warranty. Carbon Dioxide sensors or transmitters for HVAC, Building Automation Systems, or ANSI/ASHRAE Standard 62.1 2007. Typical applications include: schools, office buildings, auditoriums, gymnasiums, shopping malls, theatres, Demand Control Ventilation, or economizers.
- Universal outputs (0-5 VDC, 0-10 VDC, and 4-20 mA)
- 0 to 2,000 ppm range (default on each unit)
- Infrared Sensing Technology (Based on single beam)
- Outputs, Setpoints, Override available for each unit
- ABC Logic Automatic Calibration Software
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/20K-IM-4'-GD - ACI
Automation Field Components
20,000 Ohm Thermistor, Immersion, Machined Well, 4', Galvanized Enclosure
A/AN-BC-D-12'-BB - ACI
Automation Field Components
10,000 Ohm Thermistor w/11K Shunt, Duct, 12', NEMA 3R Enclosure
A/3K-R2O - ACI
Automation Field Components
3,000 Ohm Thermistor, Room (R2), Override
A/CP-A-8'-GD-NIST - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Copper Averaging, 8', Galvanized Enclosure, NIST Cert
A/RH5-CP-D-4X - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 5% Accuracy, 10,000 Ohm Thermistor (Type II), NEMA 4X Enclosure
A/100-2W-BP-6'CL2P - ACI
Automation Field Components
100 Ohm (Two Wire) RTD, Bullet Probe, 1", 6' Plenum Cable
A/RH5-CP-O - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 5% Accuracy, 10K Ohm Thermistor (Type II), Euro Enclosure
A/RH1-20K-R - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 1% Accuracy, 20K Ohm Thermistor