10,000 Ohm Thermistor (Type III), Duct, Without Box, 4', 20' Plenum Cable
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
121418
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/AN-DO-4'-20'CL2P - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The plenum rated ACI CL2P cable (shielded) is rated from -40 to 302°F (-40 to 150°C). With an integrated mounted flange, these sensors provide a predictable and accurate output over the specified temperature range. Each sensor is double encapsulated and manufactured for long-term quality.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/DLP-500-P-U-D-A-0-A-0P-S - ACI
Automation Field Components
Differential Low Pressure, 500 Pascal, Unidirectional, LCD Display, +/-0.5% Accuracy, 0-10VDC Output, 4-20mA output, No Nist, Standard
BN2110-D-8-PB - ACI
Automation Field Components
BACnet MS/TP, Modbus RTU, Temperature, Duct, SS, 8", Plastic Enclosure
A/RH2-1K-2W-D-NIST - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, 1,000 Ohm RTD, Euro Enclosure, NIST Cert (Temp)
A/100-3W-R2 - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Room (R2)
A/CP-R-EXPL - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Hazardous, Room (R), 2"
A/RH2-AN-O - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, 10,000 Ohm Thermistor (Type III), Euro Enclosure
A/CP-A-8'-4X - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Copper Averaging, 8', NEMA 4X Enclosure
EPC2GFSB - ACI
Automation Field Components
Analog Input (0-5VDC), Pressure Output (0-10PSI), Dual Valve, Exhausts on Power Failure , Gauge, Steel Enclosure, (0-10V, 0-15V 0-20mA), (0-15PSI, 0-20PSI)