A/AN-DO-18' - ACI
Automation Field Components
10,000 Ohm Thermistor (Type III), Duct, Without Box, 18'
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
121412
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/AN-DO-18' - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
10K Ohms @ 77 Deg F (25 Deg C) Type III Thermistor The standard duct without box configuration has a mounting flange for quick installation and etched-teflon leads. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration. Additional options include: plenum rated cable and quick connects for direct termination to male VAV-Controller inputs.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/50K-DO-8'-20'CL2P - ACI
Automation Field Components
50,000 Ohm Thermistor, Duct, Without Box, 8', 20' Plenum Cable
A/CP-DO-12'-20'CL2P - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Duct, Without Box, 12', 20' Plenum Cable
A/100-3W-I-6'-4X - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Immersion, Welded Well, 6', NEMA 4X Enclosure
A/RH1-TTM1K-RP2-10'-4X-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, 10' Plenum, NEMA 4X Enclosure, ± 1% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)
A/DIFF-ENT - ACI
Automation Field Components
Enthalpy, Differential Enthalpy Changeover Control, Indoor vs Outdoor, 24 VAC Form 1C Relay Contact
A/AN-A-24'-GD - ACI
Automation Field Components
10,000 Ohm Thermistor (Type III), Copper Averaging, 24', Galvanized Enclosure
LE11300 - ACI
Automation Field Components
Transformer, LE Series, PV:120 VAC, SV:24 VAC, VA:40, HUB: 1TF
EFP2GFS - ACI
Automation Field Components
Floating Point Input (45 sec), Pressure Output (0-15PSI), Dual Valve, Exhausts on Power Failure, Gauge, (90, 60, 120 sec), (0-15PSI, 0-20PSI)