A/3K-A-8'-GD - ACI
Automation Field Components
3,000 Ohm Thermistor, Copper Averaging, 8', Galvanized Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
119789
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/3K-A-8'-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The galvanized metal box-bendable copper averaging configuration has a mounting flange for quick installation and a foam pad to dampen vibrations. The copper capillary houses sensing elements which are wired in a series/parallel configuration to provide an averaged output. 3K Ohms @ 77 °F (25 °C) Thermistor
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/TT1K-INW-6'-1-PB - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Immersion, No Well, 6', Plastic Enclosure, 1-5VDC Output
A/10KS-RA-18'-PB - ACI
Automation Field Components
10,000 Ohm Thermistor, Rigid Probe Averaging, 18', Plastic Enclosure
A/TB-8.5-1-XXX-BO - ACI
Automation Field Components
Empty 8.5 oz Nalgene Bottle, 1 Sensing Point, Rated to -100ºC
A/DLP-750-P-B-N-B-3-A-0P-S - ACI
Automation Field Components
Differential Low Pressure, 750 Pascals, Bidirectional, No Display, 0.25% Accuracy, w/ Pitot Tube and Din Rail, 4-20mA Output, No Nist, Standard
A/DLP-010-W-U-N-B-0-C-0P-S - ACI
Automation Field Components
Differential Low Pressure, 10 inWC, Unidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 0-10VDC Output, No Nist, Standard
A/RH3-20K-D-4X - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 20,000 Ohm Thermistor, NEMA 4X Enclosure
A/TUC2-CP-0151 - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Setpoint, w/ Override, LCD
A/RH3-TTM1K-O-4X-4 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, NEMA 4X Enclosure, ± 3% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)