A/1K-3W-RA-24'-4X - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, Rigid Probe Averaging, 24', NEMA 4X Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
140189
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/1K-3W-RA-24'-4X - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI Platinum Rigid Averaging features a stainless steel probe with Etched Teflon colored lead wires to differentiate the sensor types. The three-wire “-3W” option should be ordered when using with a 3-Wire temperature transmitter or sensor configuration on your building management system or PLC (Programmable Logic Controller). The purpose of the 3rd wire is to compensate for external lead wire resistance that affects the accuracy of your sensor output. ACI recommends the use of 18 AWG lead wires to reduce external lead wire resistance when using a Platinum RTD. The rigid averaging sensors include a continuous sensing element, which covers the entire length of the probe. This allows for a better average temperature over the entire length of the sensor when compared to that of a single point duct sensor or multi-point averaging sensor. These sensors are hermetically sealed with epoxy to ensure that moisture and other contaminants can’t affect the sensing element. The Rigid Averaging sensor also includes a foam pad to seal the duct and dampen vibrations once installed. The sensor length should be determined by the width or diameter of your duct such that the sensor covers most of the internal width or height of the duct. Our standard enclosure options include the “-GD” galvanized or “-PB” plastic duct enclosure with hinged cover. On larger ducts, our Platinum bendable copper averaging sensor can be used for larger ducts and increased coverage area. This series can be ordered with optional NEMA/IP rated weather proof enclosures and NIST Certificates as referenced in the ordering grid. Applications: Roof Top Units, Air Handlers, Monitoring Duct Supply/Discharge/Return/Mixed Air Temperatures
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/100-3W-PO-4'-20'CL2P - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Probe Only, 4', 20' Plenum Cable
A/TT100-INW-4'-1-GD - ACI
Automation Field Components
Transmitter w/ 100 Ohm RTD, Immersion, No Well, 4', 1-5VDC Output
A/CP-RA-12'-GD - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Rigid Probe Averaging, 12', NEMA 3R Enclosure
A/1.8K-RA-18'-GD - ACI
Automation Field Components
1,800 Ohm Thermistor, Rigid Probe Averaging, 18', Galvanized Enclosure
A/RH2-TTM1K-R2-2 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 2-10VDC (Temp Output)
A/TT1K-R2SO-2-G5 - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Room (R2) w/ Setpoint and Override, 2-10VDC Output
A/1K-3W-BP - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, Bullet Probe, 1"
LE15013 - ACI
Automation Field Components
Transformer, LE Series, PV:120/208/240/480 VAC, SV:24 VAC, VA:75, HUB: 2TF, Manual Reset