A/1K-3W-HT-I-6'-GD - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, High Temperature Immersion, Welded Well, 6', Galvanized Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
120412
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/1K-3W-HT-I-6'-GD - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The ACI High Temperature Immersion Series sensors and transmitters are a single point immersion sensor featuring a three wire RTD sensor assembly using Nickel Fiberglass Lead wires, a 316 Series stainless steel probe, and a Machined 304 SS Steel thermowell. The “INW” version of the product can be ordered without the thermowell for applications in which there is an existing thermowell, increased design parameters or other materials are required for higher corrosion resistance. The three wire sensors can be used with a two-wire transmitter by connecting the two (Red) colored wires to one of the RTD Terminal blocks with the 3rd wire (White) wire going to the second RTD Terminal block. The purpose of the 3rd wire is to compensate for external lead wire resistance that will affect the accuracy of your sensor output when using with a three-wire temperature transmitter or sensor configuration on your Building Management System or PLC (Programmable Logic Controller. ACI recommends the use of 18 AWG lead wires to reduce the external lead wire resistance when using a Platinum RTD. The operating specifications are for both the sensor and transmitter as designated in the specification table. Standard enclosure options include the “-GD” Galvanized or “-BB” Aluminum weather proof enclosure. NIST Certificates are available for all of the configurations listed in the ordering grid on the back of the product data sheet. For best accuracy, ACI recommends the use of the TTM100 or TTM1K Series Matched transmitters with a 3 or 5 Point NIST Calibration Certificate since they include a second calibration step in which the RTD and transmitter are calibrated together as a system, which removes most of the sensor error over the calibrated temperature span of the transmitter. Applications: Burners, Boilers, Stacks, Exhaust, Incinerators, Ovens, Plastics Processing, Process Heating, Process Control, Steam Lines
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/CP-PO-8'-NIST - ACI
Automation Field Components
10,000 Ohm Thermistor (Type II), Probe Only, 8', NIST
A/TTM1K-RA-36'-4-BB - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD (NIST Cert), Rigid Probe Averaging, 36', NEMA 3R Enclosure, 4-20mA Output
A/1K-3W-HT-INW-6'-GD - ACI
Automation Field Components
1,000 Ohm (Three Wires) RTD, High Temperature Immersion, no Well, 6' 316SS, Galvanized Enclosure
A/DLP-2D5-W-U-N-B-1-C-3P-S - ACI
Automation Field Components
Differential Low Pressure, 2.5 inWC, Unidirectional, No Display, 0.25% Accuracy, w/ Pitot Tube, 0-10VDC Output, 3 Point Nist, Standard
A/50K-O-BB - ACI
Automation Field Components
50,000 Ohm Thermistor, Outside Air, NEMA 3R Enclosure
A/1K-LTS-GD-10' - ACI
Automation Field Components
1,000 Ohm RTD, 2" Freezer Probe 316SS, Galvanized Enclosure, 10'
BAC-BOX-0 - ACI
Automation Field Components
BACnet IP Output, Q-Controller
A/RH3-1K-NI-O-SUN - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 3% Accuracy, 1,000 Ohm Nickel RTD, Sun Shield