A/1.8K-I-2.5'-BB - ACI
Automation Field Components
1,800 Ohm Thermistor, Immersion, Welded Well, 2.5', NEMA 3R Enclosure
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
124109
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/1.8K-I-2.5'-BB - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The metal bell box, with well configuration has a NEMA 3R rating and is designed for wet environments. It has male 1/2 inch NPT threads and the sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration. ACI also standardizes with etched Teflon lead wires and 2 part wells. ACI immersion temperature sensors are designed for HVAC, Building Automation Systems, and light industrial applications. Specific applications include: chillers, hot water systems, tanks, and boilers. NOTE: Welded thermowells are not intended for moving water or high pressure service. Fluid velocity and wake frequency are primary factors in well failure. Machined thermowells should be used in these types of applications.
- Negative temperature coefficient
- Double encapsulated sensor
- NEMA 3R enclosure
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :ACI branded products are imported from United States of America factory specially to order. The estimated delivery time of the products is 5 weeks. In this product group, an additional shipping and customs fee of 450EUR is charged for orders under 4,000EUR.
A/3K-INW-6'-PB - ACI
Automation Field Components
3,000 Ohm Thermistor, Immersion, No Well, 6', Plastic Enclosure
A/TT1K-D-12'-1-PB - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD, Duct, 12', Plastic Enclosure, 1-5VDC Output
A/RH3-RP2-6'-EH - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Remote Probe, ± 3% Accuracy, 6' Plenum
A/DLP-003-W-U-N-B-0-A-0P-S - ACI
Automation Field Components
Differential Low Pressure, 3 inWC, Unidirectional, No Display, 0.25% Accuracy, No Pitot Tube, 4-20mA Output, No Nist, Standard
A/TUC2-0-5V-0006 - ACI
Automation Field Components
0-5VDC Output, Setpoint, w/ Override, LCD
A/TUCH2-CP-0127 - ACI
Automation Field Components
LCD, RH2%, SET, O/R, DEG F
QTS-61211X-E000000 - ACI
Automation Field Components
Toxic Gas Sensor, Hydrogen, 0-2000 PPM, 4-20mA Output loop powered, Industrial NEMA 4X, Aluminum Sensor Housing
A/10K-E1-FA-24'-GD - ACI
Automation Field Components
10,000 Ohm (E1) Thermistor, Flexible Cable Averaging, 24', Galvanized Enclosure