Greystone
Greystone marka ürünlerinin Türkiye satışını Kontrolyum Otomasyon Sistemleri olarak gerçekleştirmekteyiz. Tüm Greystone ürünleri Kontrolyum.com adresinde indirimli fiyatlar satışa sunulmaktadır.
CD2RMCC02XSP00 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, No relay, Override switch, 0 - 10,000 ohms
CD2RMCC02RXXXX - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, No override, No setpoint
CD2RMCC02RXP02 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, No override, 2000 - 3000 ohms
CD2RMCC02RXP01 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, No override, 20,000 - 30,000 ohms
CD2RMCC02RXP00 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, No override, 0 - 10,000 ohms
CD2RMCC02RSXXX - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, Override switch, No setpoint
CD2RMCC02RSP02 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, Override switch, 2000 - 3000 ohms
CD2RMCC02RSP01 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, Override switch, 20,000 - 30,000 ohms
CD2RMCC02RSP00 - Greystone
Mahal Tip Karbondioksit Sensörü
Room Carbon Dioxide Sensor, 0-2,000 ppm, Concealed LCD, 100 Ohm Plat. IEC 751, 385 Alpha, thin film, Adjustable relay, Override switch, 0 - 10,000 ohms
CD2DTFXXX - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, No temperature sensor, No relay
CD2DTFXXR - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, No temperature sensor, Adjustable relay
CD2DTF59X - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm±1%, B-3455 +/- (25/85), No relay
CD2DTF59R - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm±1%, B-3455 +/- (25/85), Adjustable relay
CD2DTF24X - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm, type 2, NTC Thermistor, ±0.2 C, No relay
CD2DTF24R - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm, type 2, NTC Thermistor, ±0.2 C, Adjustable relay
CD2DTF20X - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 20,000 Ohm, NTC Thermistor, ±0.2 C, No relay
CD2DTF20R - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 20,000 Ohm, NTC Thermistor, ±0.2 C, Adjustable relay
CD2DTF14X - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C c/w 11K shunt resistor, No relay
CD2DTF14R - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 10,000 Ohm, type 3, NTC Thermistor, ±0.2 C c/w 11K shunt resistor, Adjustable relay
CD2DTF13X - Greystone
Kanal Tip Karbondioksit (CO2) Sensörü
Duct Carbon Dioxide Sensor, 0-2,000 ppm, Polycarbonate enclosure with hinged gasketed cover,thread adapter and cable gland fitting, 1000 Ohm Nickel, Class B, DIN 43760, No relay