Differential Low Pressure, 1 inWC, Bidirectional, 0.50% Accuracy, No Pitot Tube, 0-5VDC Output, No Nist, Standard
This item is temporarily out of stock.
It can be backordered right now, and we can ship it within 5 weeks.
0
147330
ACI
U.S.A.
{{CMP.TITLE}}
- Features
- Comments (0)
-
Data Sheet
A/DLP-001-W-B-D-A-0-B-0P-S - ACI
Automation Field Components
download pdfPlease contact us if you need any other document this item may have.
You can only download Technical Document (Datasheet) on this section.
The DLP Series is based on a piezoresistive, silicon sensing element which senses Differential Pressure and provides an analog output. The hinged cover on the DLP can be easily opened using the integrated locking tab on the side of the enclosure. This allows for easy access to the zero function and field selectable ranges and outputs. The DLP Series also includes an optional, five-digit LCD for installation and monitoring support. Field selectable analog outputs include 0-5 and 0-10 VDC, or 4-20 mA which correlate to a specific uni or bi-directional pressure range from 0-0.1” up to 0-40” of water column, depending on your model selection. Each unit must be ordered with the specific pressure range needed to meet desired application requirements. Options include a Pitot Tube or Din Rail Clip.
Applications: Building and Duct Static Pressure, Filter Monitoring, Air Flow Measurement, and Process Control
The DLP Series is covered by ACI's Five (5) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's website, www.workaci.com.
Warranty :This product is under warranty for 2 years against manufacturing and material defects from the date of invoice. The invoice for the products also stands in place of the warranty certificate, a separate document is not issued.Delivery Information :The stock quantity information reported in the product details is up to date. Products in stock can be shipped immediately. Products that are not in stock and whose delivery time is separately reported are shipped when the supply period is completed.
A/100-3W-D-6'-GD - ACI
Automation Field Components
100 Ohm (Three Wires) RTD, Duct, 6', Galvanized Enclosure
A/RH2-0.1CP-O-NIST - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, High Accuracy 10,000 Ohm Thermistor (Type II), NIST Cert
A/TTM1K-BP-4-4X-20'CL2P - ACI
Automation Field Components
Transmitter w/ 1,000 Ohm RTD (NIST Cert), Bullet Probe, 1", 20' Plenum Cable, NEMA 4X Enclosure, 4-20mA Output
A/RH2-100-3W-D - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), ± 2% Accuracy, 1,000 Ohm (Three Wires) RTD, Euro Enclosure
A/RH3-TT1K-R2-2 - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 3% Accuracy, Transmitter w/ 1,000 Ohm RTD, 2-10VDC (Temp Output)
A/TUC2-4-20MA-0017 - ACI
Automation Field Components
4-20mA Output, Setpoint, LCD
A/RH2-R-LCD-010 - ACI
Automation Field Components
Relative Humidity, Room, Humidity with LCD, ± 2% Accuracy, 0-10 VDC
A/RH2-1K-NI-D - ACI
Automation Field Components
Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, 1,000 Ohm Nickel RTD, Euro Enclosure